Hitachi Gigabit Router GR2000 Series Enhanced Version Operations - Device Management Overview
7-20 GR2K-GA-0015
Ver. 07-02
7.4.3 ATM line cannot be connected
Check out the status of NIF and Line as described below when the cause of a
communication failure is judged to lie in ATM line.
7.4.3.1 Checkout on the Status
(a) NIF Status Checkout:
Checkout on the NIF status using show nif commands. Refer to Table 7-18.
(b) Line Status Checkout:
Checkout on the Line status using show interfaces commands. Refer to Table 7-19.
Table 7-18 ATM NIF Status Checkout/Action
No. NIF Status Cause Action
1 active The NIF is operating normally. Inspect line status according to Table 7-19.
2 mismatch For installed NIF, configured line cannot
be used under control of this NIF.
(Installed NIF and line configuration
information do not match.)
Check whether installed NIF is correct, or line
configuration information is correct.
3 unused Line configuration information is not
defined under this NIF.
Define configuration information for the line to
be used.
4 closed Operation of this NIF is suspended by the
close nif command.
Ensure that the NIF board to be used is
installed, and set this NIF to active by using the
free nif command.
5 fault This NIF is faulty. Obtain the log message for the subject line
using show logging command, and take
necessary troubleshooting actions in
accordance with the obtained log message
(Chapter 5, “Log Messages,” in GR2000
Operations Log and MIB Reference).
6 initialized This NIF is restarting after error detection. Same as above.
7 locked Operation of this NIF is suspended by
configuration information.
Ensure that the NIF board to be used is
installed, and set this NIF to active by altering
the configuration information.
Table 7-19 ATM Line Status Checkout/Action
No. Line Status Cause Action
1 active up This line is operating normally. Inspect VC status according to Table 7-20.
2 active down This line has line error. Obtain the log message for the subject line using show
logging command, and take necessary troubleshooting
actions in accordance with the obtained log message
(Chapter 5, “Log Messages,” in GR2000 Operations Log
and MIB Reference).
3 mismatch For installed line, configured line
cannot be used under control of
this NIF. (Installed line and line
configuration information do not
match.)
Check whether installed line is correct, or line
configuration information is correct.
4 unused Line configuration information is
not defined under this line.
Define configuration information for the line to be used.